Login | Register
公司介绍s
Home > Tags > Non-Integral Sheathed Electrical Cable

Non-Integral Sheathed Electrical Cable

Non-Integral Sheathed Electrical Cable Non-integral sheathed electrical cables are a type of flexible wiring solution designed for power transmission and distribution in residential, commercial, and industrial applications. Unlike integral sheathed cables, which have insulation and sheathing fused into a single layer, non-integral sheathed cables feature separate layers of insulation and an external protective sheath. This design enhances durability, flexibility, and safety, making them suitable for various installation environments. Construction and Components A typical non-integral sheathed cable consists of the following layers: 1. Conductors: Usually made of copper or aluminum, these carry electrical current. They may be solid or stranded, with stranded conductors offering better flexibility. 2. Insulation: Each conductor is individually insulated with materials like PVC (Polyvinyl Chloride), XLPE (Cross-Linked Polyethylene), or rubber to prevent short circuits and electrical leakage. 3. Filler/Bedding: Some cables include fillers or bedding materials to maintain a round shape and improve mechanical strength. 4. Sheath: An outer protective layer, typically made of PVC, LSZH (Low Smoke Zero Halogen), or thermoplastic, shields the conductors from moisture, abrasion, chemicals, and mechanical damage. Key Features and Advantages - Flexibility: The stranded conductors and non-integral sheath allow easier bending and routing in tight spaces. - Durability: The separate sheath provides enhanced protection against environmental factors, extending cable lifespan. - Safety: Flame-retardant and LSZH sheathing options reduce fire hazards and toxic emissions in case of combustion. - Versatility: Suitable for fixed installations, temporary wiring, and outdoor use (if UV-resistant sheathing is used). - Easy Identification: Color-coded insulation simplifies wiring and maintenance. Applications Non-integral sheathed cables are widely used in: - Building Wiring: Powering lighting, sockets, and appliances. - Industrial Machinery: Supplying flexible connections to motors and control systems. - Renewable Energy: Connecting solar panels and wind turbines. - Underground/Outdoor Installations: When protected by conduit or direct burial-rated sheathing. Standards and Compliance These cables must meet international standards such as IEC, BS, or NEC, ensuring performance under specified voltage ratings (e.g., 300/500V or 450/750V) and temperature ranges. Conclusion Non-integral sheathed electrical cables offer a reliable, adaptable, and safe solution for diverse electrical installations. Their multi-layer construction balances flexibility with robust protection, making them a preferred choice for engineers and electricians worldwide. Proper selection based on voltage, environment, and regulatory requirements ensures optimal performance and safety.

Products

Category:
view:
  • UL2464 PVC Non-Integral Sheathed Multi-Conductor Cable

    UL2464 PVC Non-Integral Sheathed Multi-Conductor Cable

    Category: UL Certified Cables
    Browse number: 217
    Number:
    Release time: 2025-09-23 17:30:20
    A PVC Non-Integral Sheathed Multi-Conductor Cable is designed for reliable and flexible electrical connections in industrial and commercial applications. Featuring multiple insulated conductors without a single outer sheath, this cable allows for easy routing and customization in control panels, machinery wiring, and automation systems. Constructed with high-quality copper conductors and durable PVC insulation, it provides excellent resistance to abrasion, moisture, and chemical exposure. Widely used in power distribution, signal transmission, and control circuits, PVC non-integral sheathed multi-conductor cables deliver safe, efficient, and long-lasting performance in demanding environments.
  • UL2517 PVC Non-Integral Sheathed Multi-Conductor Cable

    UL2517 PVC Non-Integral Sheathed Multi-Conductor Cable

    Category: UL Certified Cables
    Browse number: 249
    Number:
    Release time: 2025-09-25 11:53:04
    Non-Integral Sheathed Multi-Conductor Cable is designed for applications requiring multiple insulated conductors bundled together within a protective outer jacket. This construction provides excellent electrical performance, simplified installation, and enhanced durability in industrial and commercial environments. Commonly used in control systems, signal transmission, automation equipment, and power distribution, these cables ensure reliable connectivity while resisting abrasion, moisture, and environmental stress. With flexible design options and compliance with industry standards, non-integral sheathed multi-conductor cables deliver safe, efficient, and long-lasting performance for a wide range of wiring applications.
  • UL2586 PVC Non-Integral Sheathed Multi-Conductor Cable

    UL2586 PVC Non-Integral Sheathed Multi-Conductor Cable

    Category: UL Certified Cables
    Browse number: 217
    Number:
    Release time: 2025-09-25 14:15:25
    Non-Integral Sheathed Multi-Conductor Cable is designed for applications requiring multiple insulated conductors bundled together within a protective outer jacket. This construction provides excellent electrical performance, simplified installation, and enhanced durability in industrial and commercial environments. Commonly used in control systems, signal transmission, automation equipment, and power distribution, these cables ensure reliable connectivity while resisting abrasion, moisture, and environmental stress. With flexible design options and compliance with industry standards, non-integral sheathed multi-conductor cables deliver safe, efficient, and long-lasting performance for a wide range of wiring applications.

News

Category:
No search results found!

Case

Category:
No search results found!

Video

Category:
No search results found!

Download

Category:
No search results found!

Job

Category:
No search results found!

Featured Products

No search results found!

This website uses cookies to ensure you get the best experience on our website.

Accept Reject